Ann Rheum Dis

HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH REGISTER
[Advanced]

The most recent version of this article was published on 1 April 2007

Ann Rheum Dis. Published Online First: 15 November 2006. doi:10.1136/ard.2006.060277
Copyright © 2006 BMJ Publishing Group Ltd & European League Against Rheumatism

This Article
Right arrow Full Text (Rapid PDF)
Right arrow All Versions of this Article:
ard.2006.060277v1
66/4/464    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this link to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Maheu, E.
Right arrow Articles by Dougados, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Maheu, E.
Right arrow Articles by Dougados, M.

Extended Report

Reproducibility and sensitivity to change of 4 scoring methods for the radiological assessment of osteoarthritis of the hand

Emmanuel Maheu 1*, Christian Cadet 2, Sylvie Gueuneugues 3, Philippe Ravaud 4 and Maxime Dougados 5

1 Saint-Antoine Hospital, France
2 Rheumatology Office, France
3 Universit Diderot, Paris VII, Unité d’épidémiologie clinique et de Biosta, France
4 Université Diderot, Paris VII, Unité d’épidémiologie clinique et d, France
5 Paris-Descartes University, Medicine Faculty ; AP-HP, Cochin Hospital, Rheumatology B Department, France

* To whom correspondence should be addressed. E-mail: emaheu{at}wanadoo.fr.

Accepted 2 November 2006


*  Abstract

Hand osteoarthritis (0A) could be a relevant model to study OA progression in structure-modification trials. Various methods are proposed to radiologically assess hand OA and its progression.

Objective: To compare intra-, interreader precision and sensitivity to change of 4 radiological scoring methods proposed in hand OA.

Methods: Two trained readers scored separately 105 pairs of radiographs (baseline ; year 1), selected from patients enrolled in a randomised controlled trial, for interreader reliability and sensitivity to change. They scored twice 60 pairs among the 105 for cross-sectional and longitudinal intrareader reliability. Radiological hand OA assessment used : Global ; Kellgren-Lawrence (KL) ; Kallman ; and Verbruggen scoring methods. Inter- and intrareader reliabilities were studied using intra-class coefficient (ICC) and Bland-Altman method. Sensitivity to change was compared by calculating the standardised response means (SRM).

Results: Transversal intrareader reproducibility ICCs ranged from 0.922 to 0.999. Verbruggen ranked the highest, followed by KL and Kallman methods. Interrater reliability was higher for the Verbruggen followed by the KL, global and Kallman scores (ICC : 0.706 to 0.999). Longitudinal intrareader reliability (baseline - year 1) was better using Kallman and KL (ICC 0.986 and 0.990), followed by Verbruggen (0.941) or global methods (0.939). SRMs ranged from 0.24 (KL) to 0.29 (Kallman).

Conclusion: All 4 methods compared well with respect to reliabilities. However, Verbruggen and Kallman performed better. The most sensitive to change was the Kallman followed by Verbruggen and global scores. This study also suggests that structural changes could be detected in hand OA over a 1-year period.


Keywords: Kallman, Verbruggen, Kellgren and Lawrence scales, hand OA, radiographic assessment, reliability of various scoring methods, sensitivity to change







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH REGISTER
Terms and conditions relating to subscriptions purchased online  ¦  Website terms and conditions  ¦  Privacy policy
Copyright © 2006 BMJ Publishing Group Ltd & European League Against Rheumatism